You can download and install the Visualiser tool for Windows on your Windows PC below for free. You can start the tool via the shortcut on your worksheet. Then connect your PC via USB to the PPC/MoCo module to configure the various parameters. Once configured, you can close this software and disconnect the USB because the module then works autonomously.
PPC.O4:
With the SCAN button you can locate the module, and then set protokol and possibly upgrade the module
MoCo and MoCo2:
With the MoCo and the MoCo2 with 2 additional pulse inputs, there are a lot more possibilities
  • Press SCAN to retrieve the module
  • Press UPGRADE to upgrade the MoCo, the FW version is displayed as a reverse date.
  • Debug log button: Here you can read the data from the P1 in the form of Obis numbers, useful for debugging. Exit to return
  • Modbus slave address setting 1...247
  • Set protocol of P1 meter, Important: Select "No P1" if you do not have a P1 meter and want to convert only input pulses to Modbus
  • Out1 and Out2:
    • As pulse out: select which meter readings from the P1 are to be converted to consumption pulses and optionally specify the weight of each pulse. e.g. Import H, diviser 1: means, Out1 outputs 1 pulse per 1 Wh of daily consumption. Operation: Every few seconds MoCo reads the counter readings, the difference between the current counter reading and the previous counter reading is converted to consumption pulses according to the set weight(divider) and these come out on the Out1.
    • As Smart grid contact: Out1 and Out2 can be used as smartgrid ready output (low power max.40VDC, 50mA). With an optional 12VDC power relay these can be converted to a power output, see module PEM01-012 on this website. Both outputs can each be set as an ON/OFF with simple switching logic based on consumption or injection.If import or export(=injection) is greater than set Level then relay ON, and OFF again as soon as consumption falls below Level-Diff. Only on export can diff> Level and thus go negative.
    • Logic: In the example on the left: OUT2 turns ON from import>3000 Watts for 3 minutes and turns off after 7 minutes less than 1500 Watts import(=consumption). OUT1 translate import/consumption to 1Wh pulses
  • At Input pulses you can enter a start value. As for the weight , at ReMI /ELAN Weight set as 1000, at MEMo3 Weight set as 1, see manual MoCo2.